Ce Approved English Menu Reliable Multi Parameters Water Analyzer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2017-09-24 03:31

  • Browse the number:

    100

Send an inquiries
+
Shandong Dongrun Instrument Science and Technology Co., Ltd.
Contactaixin:

Mr. Bobby Jiang(Mr.)  

Email:

telephone:

phone:

Arrea:

Shandong

Address:

No. 1, Xiulin Road, Laishan Economic Development Zone, Yantai, Shandong, China 064003

Website:

http://cndongrun.aozbao.com/

+

DR-5000 multi-parameter water analyzer is a highly integrated measured parameter wall-mounted equipment which can test the parameter all in one, compact structure, with input probe, with high degree of intelligence and flexibility, widely used in water supply, municipal, farming and other industries.

 


Product Feature  
 • Can be connected with an analog or digital sensor, readily assembled into a conventional five-parameter water quality analysis instrument.
 • DC12V can supply current of less than 500mA, can use solar powered.
 • Controller whole intelligent, automatic identification of sensor.
 • Display the SD card storage data on the computer.
 • Can calibrate the sensor both in the scene and in the lab.
 • 4.3-inch LCD display, showing beautiful, easy manipulation, can display multiple parameters in the same time.
 • With power protection and automatic recovery function call, parameter settings after power is not lost.
 • No reagent filling, no reagent consumption.
Specifications
 • Power:85-265VAC , 20W;
 • Meter size (width X height X thickness): 320X260X130:
 • 4-20mA analog and RS485 digital output, MODBUS protocol;

Specification
Temperature  
 
Principle platinum resistance temperature sensor
Range -10 ~ 150°C
Accuracy ± 0.2 °C
Installation bracket mounting
PH / ORP
Principle:  glass electrode method
Range -2000 ~ + 2000mv / -2 ~ 14 pH
Sensitivity ≤ ± 0.5mV / ± 0.01 pH
Compensation 0 ~ 105 °C
Response Time <50 seconds
Installation bracket mounting
Dissolved Oxygen Sensor

 
Principle Fluorescence
Measuring Range 0 ~20.00 mg/L, -5 ~60 °C
Accuracy ≤0.1 mg/L
Resolution ≤0.01 mg/L
Compensation  0 ~ 50 °C
Response Time 60 seconds;
Repeatability 0.05mg/L
Installation bracket mounting
Conductivity Sensor
Principle Electromagnetic method
Measuring Range 0~200~2,000~20000µS/cm.
0~2~20~200~2000mS/cm
Temperature -10~200 °C
Repeatability ±1%
Accuracy ±0.01 %
Calibration Standard Solution KCL,25 °C
Compensation -20 ~100 °C
Response <60 seconds
Installation bracket mounting
Turbidity Sensor
Principle near-infrared 90°scatter
Range 0.001-4000NTU
Resolution ≤0.01NTU or 0.1NTU
Accuracy ±0.5%FSD
Reproducibility ±1.0%F.S