Kg316t Digital Time Switch
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Zhejiang
-
Validity to:
Long-term effective
-
Last update:
2017-08-17 13:28
-
Browse the number:
80
+
Yueqing Winston Electric Co., Ltd.
- Contactaixin:
Mr. Tony(Mr.)
- Email: telephone: phone:
-
Arrea:
Zhejiang
Address:B2 Building, Fangdouyan Industrial Zone, Liushi Town, Wenzhou, Zhejiang, China 325604
- Website:
+
KG316T digital Time Switch
Function:
The product can open and close all kinds of power supply automatically according to the user's time.
The control objects can be road lamp, neon lamp, billboard, producing equipment, broadcast TV,
and all that the circuit fixtures and home appliances need setting time to control.
Technical index:
1. Working voltage: 220V/50Hz
2. Applicable voltage range: 160V~240V
3. Switch capacity: Residence 25A, Sensible 20A
4. Consumed power: <1W
5. No effect from power cut, charge automatically inside
6. Can set 10 ON and 10 OFF at most everyday, manual and automatically
7. Work circularly according to designed procedure by week or by day
8. Time-lapse range: 1 min~ 168 Hrs
9. Environmental temperature: -20ºC~60ºC
10. Time error: <0.5s/day
11. Environmental humidity:<95%
12. Net weight: 430g
Instructions
Time setting
When reading the manual, user shall make clear the keys on the panel and operate it.
1. Adjust clock:
The products have been adjusted well when ex-factory. If you need readjust, please press the clock key, at the same time, press the week key,
thus finish the week adjustment. The rest may be deduced by analogy.
2. Set the first open time:
Press the timer key, LCD screen shall appear (see picture 1), then press hour key and second key,
put in the open time.
3. Set the first close time:
Press the timer key again, LCD screen shall appear (see picture 2), then press hour key and second
key, put in the close time.
4. Press the timer key continually, the bottom left of LCD screen shall appear in turn (two ON and
two OFF, ...six ON and six OFF, ...ten ON and ten OFF), refer to step 2 and 3 to set future open
and close time. If open and close one time in one day, you must press Reset/Recall key to remove
all the deposited time (two ON and two OFF, ...six ON and six OFF, ...ten ON and ten OFF),
making the LCD show "--:-- "mark.
5. After finishing the timer setting, press clock key, or not press any key within 30 seconds,
making LCD show the Beijing time.
6. After engaging the power supply, if the indicator lamp only shows red, which means the circuit
is with electricity. If the indicator lamps show both red and green, which means the switch is
connected.
7. Pressing Auto/Manu key can open or close circuit directly. If you want the switch automatically
work, please press Auto/Manu key first, and adjust the mark under the LCD to the close position,
and then press it again to adjust to the Auto position. For example: Open at 18:30 P.M.
(See picture 3, introduced in step 2) and close at 23:20 P.M. automatically everyday
(See picture 4, introduced in step 3), and the following is to adjust the LCD to be"--:-- "marked (Introduced in step4), and operate as introduced in step 5,6, 7.
8. Press timer key, and then press week key, thus can set same or different combinations of Mon,
Wed, Fri or Tue, Thu, Sat, or Mon, Tue, Wed, or Thu, Fri, Sat. and set same from Mon to Fri,
or Sat. to Sunday.
Mounting size
Connection methods
1. Direct control connection
The controlled equipment shall be single-phase power supply, and the power shall not beyond the rated capacity (Resistibility loading 25A,
sensibility loading 20A), is available for direct control method. See picture 1.
2. Single phase and extended capacity connection
The controlled equipment is single-phase power supply, but the power is beyond the rated capacity (Resistibility loading 25A,
sensibility loading 20A), then you shall need an AC contactor.
to extend the capacity. See picture 2.
3. Three-phases connection
The controlled equipment is three-phase power supply, which need a three-phase AC contactor connected outside. The loop of the AC contactor is AC220V, 50Hz.
See picture 3. And if the loop is AC380V, 50Hz, then see picture 4.
When you think it at fault
l If the switch has not open at the open time, or close not at the close time after opening,
it maybe the week adjustment goes wrong, please check or readjust it according to the methods
of the timer setting introduction.
l If you confirm the open and close time have been right adjusted, but the switch open or close
at the wrong time, it maybe redundant time settings have not be removed, please remove them
according to the methods of the timer setting introduction. ( Note: The timer shows "--:-- " is OK instead of "00:00".)
l If the above two are all right, but the switch doesn't work normally, maybe the Auto/Manu key
is wrongly done, please check markof open, auto, close, and adjust it to be current time, then back
at the auto position.
l If the switch has not work normally yet, please open the rear fuse cover (terminal panel), check
whether the fuse break off or not, if yes, please change it with new fuse of 0.1A~0.3A.
l If the above several methods still can't remove the faults, please contact our company or local
distributor.
Attentions
l For the equipment which has possible accident caused by the timer switch going wrong, or the
equipment which has great effect to the society such as medical treatment equipment and large-scale equipment, etc., Please don't use our timer switch.
l For the equipments (large-scale ones such as heat warehouse or refrigeratory, etc.) which have the possible great belongings
losing caused by the timer switch goes wrong, please be sure to have enough space for the properties
and performance value, and take measures such as double circuit for secure,
when you use our timer switch.
l Don't repair, disassemble, change, and check it by yourself.
l Please be sure to entrust distributor or builder.
l Don't touch terminal part after connecting power supply.
l The switch works at non-humidity, corrosion proof and free from high metal-contained gas environment. Please don't touch with oil or water.
1. AH3-3 time relay Application
2. AH3-3 time relay Specifications and parameters
3. AH3-3 time relay Normal operating conditions and installation conditions:
DH48S Digital display time relay is used in the scale of the advanced application specific integrated circuit, LED digital tube display, beautiful appearance, easy installation, digital key switch preset, stable and reliable, high precision, delay range, low power consumption advantages, is widely used in automatic control circuits for delay device.
1. Timing Range:
H:1min-99h99min
M:1s-99min99s
S:0.01s-99.99s
Normal operating conditions and installation conditions
1.1 The use of the environment: the sea disturbance height of not more than 2000 meters, ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85% -110% rated voltage; in the absence of a serious shock and explosion hazard medium, and medium, non-corrosive metal and undermine the insulation is sufficient gas and dust; in less rain and snow hit areas.
1.2 Vertical or horizontal installation.
2.1 Technical Features:
1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can be customized);
2, electrical life: ≥ 10 × 104 times;
3, Mechanical life: ≥ 100 × 104 times;
4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1;
5, use the Class: AC-15 DC-13;
6, repeated the error: "1%;
7, reset time: ≤ 1 sec;
8, power consumption: ≤ 1.5W (DH11S ≤ 3W).
Products Specification:
Rated products
General relay MK MY,LY
Thermal relay 3UA LR9 JRS1,JR28
Power relay JQX-38F JQX-40F 1Z JQX-52F JQX-58F JQX-59F JQX-60F JQX-62F 1Z 80A JQX-62F 1Z 120A JQX-62F 2Z 80A
Time relay AH3-N_ ST2P ST3P H3BA(ST4P) H3CR-A8 H3CA-A H3CA-8 ASTP-N/Y AH2-N/Y ATDV-N/Y ASY-2D ASY-3D AH3Y (ST6P)
Electromagnetic relay 58.02 56.02 55.02 55.04 57.02 57.04 60.12 60.13 70.2
Relay socket PYF-08A PYF-08A-E PYF11A PYF14A PF113A-E PF085A PS-08 P2CF-08 PY-08 PY-14 PT-08 PT-14 PTF08A PTF08A-E PTF11A PTF14A PTF14A-E PTF083A PF083A-F PF113A 90.22 90.23 PPF-011 PY-08-0
Solid state relay
Function:
The product can open and close all kinds of power supply automatically according to the user's time.
The control objects can be road lamp, neon lamp, billboard, producing equipment, broadcast TV,
and all that the circuit fixtures and home appliances need setting time to control.
Technical index:
1. Working voltage: 220V/50Hz
2. Applicable voltage range: 160V~240V
3. Switch capacity: Residence 25A, Sensible 20A
4. Consumed power: <1W
5. No effect from power cut, charge automatically inside
6. Can set 10 ON and 10 OFF at most everyday, manual and automatically
7. Work circularly according to designed procedure by week or by day
8. Time-lapse range: 1 min~ 168 Hrs
9. Environmental temperature: -20ºC~60ºC
10. Time error: <0.5s/day
11. Environmental humidity:<95%
12. Net weight: 430g
Instructions
Time setting
When reading the manual, user shall make clear the keys on the panel and operate it.
1. Adjust clock:
The products have been adjusted well when ex-factory. If you need readjust, please press the clock key, at the same time, press the week key,
thus finish the week adjustment. The rest may be deduced by analogy.
2. Set the first open time:
Press the timer key, LCD screen shall appear (see picture 1), then press hour key and second key,
put in the open time.
3. Set the first close time:
Press the timer key again, LCD screen shall appear (see picture 2), then press hour key and second
key, put in the close time.
4. Press the timer key continually, the bottom left of LCD screen shall appear in turn (two ON and
two OFF, ...six ON and six OFF, ...ten ON and ten OFF), refer to step 2 and 3 to set future open
and close time. If open and close one time in one day, you must press Reset/Recall key to remove
all the deposited time (two ON and two OFF, ...six ON and six OFF, ...ten ON and ten OFF),
making the LCD show "--:-- "mark.
5. After finishing the timer setting, press clock key, or not press any key within 30 seconds,
making LCD show the Beijing time.
6. After engaging the power supply, if the indicator lamp only shows red, which means the circuit
is with electricity. If the indicator lamps show both red and green, which means the switch is
connected.
7. Pressing Auto/Manu key can open or close circuit directly. If you want the switch automatically
work, please press Auto/Manu key first, and adjust the mark under the LCD to the close position,
and then press it again to adjust to the Auto position. For example: Open at 18:30 P.M.
(See picture 3, introduced in step 2) and close at 23:20 P.M. automatically everyday
(See picture 4, introduced in step 3), and the following is to adjust the LCD to be"--:-- "marked (Introduced in step4), and operate as introduced in step 5,6, 7.
8. Press timer key, and then press week key, thus can set same or different combinations of Mon,
Wed, Fri or Tue, Thu, Sat, or Mon, Tue, Wed, or Thu, Fri, Sat. and set same from Mon to Fri,
or Sat. to Sunday.
Mounting size
Connection methods
1. Direct control connection
The controlled equipment shall be single-phase power supply, and the power shall not beyond the rated capacity (Resistibility loading 25A,
sensibility loading 20A), is available for direct control method. See picture 1.
2. Single phase and extended capacity connection
The controlled equipment is single-phase power supply, but the power is beyond the rated capacity (Resistibility loading 25A,
sensibility loading 20A), then you shall need an AC contactor.
to extend the capacity. See picture 2.
3. Three-phases connection
The controlled equipment is three-phase power supply, which need a three-phase AC contactor connected outside. The loop of the AC contactor is AC220V, 50Hz.
See picture 3. And if the loop is AC380V, 50Hz, then see picture 4.
When you think it at fault
l If the switch has not open at the open time, or close not at the close time after opening,
it maybe the week adjustment goes wrong, please check or readjust it according to the methods
of the timer setting introduction.
l If you confirm the open and close time have been right adjusted, but the switch open or close
at the wrong time, it maybe redundant time settings have not be removed, please remove them
according to the methods of the timer setting introduction. ( Note: The timer shows "--:-- " is OK instead of "00:00".)
l If the above two are all right, but the switch doesn't work normally, maybe the Auto/Manu key
is wrongly done, please check markof open, auto, close, and adjust it to be current time, then back
at the auto position.
l If the switch has not work normally yet, please open the rear fuse cover (terminal panel), check
whether the fuse break off or not, if yes, please change it with new fuse of 0.1A~0.3A.
l If the above several methods still can't remove the faults, please contact our company or local
distributor.
Attentions
l For the equipment which has possible accident caused by the timer switch going wrong, or the
equipment which has great effect to the society such as medical treatment equipment and large-scale equipment, etc., Please don't use our timer switch.
l For the equipments (large-scale ones such as heat warehouse or refrigeratory, etc.) which have the possible great belongings
losing caused by the timer switch goes wrong, please be sure to have enough space for the properties
and performance value, and take measures such as double circuit for secure,
when you use our timer switch.
l Don't repair, disassemble, change, and check it by yourself.
l Please be sure to entrust distributor or builder.
l Don't touch terminal part after connecting power supply.
l The switch works at non-humidity, corrosion proof and free from high metal-contained gas environment. Please don't touch with oil or water.
1. AH3-3 time relay Application
AH3-3 series time relay is used ASIC and professional manufacturing technology to produce innovative time relay, with small size, light weight, delay a wide range of anti-interference ability, long life characteristics to be suitable for a variety of demanding precision, high reliability, automation and control sites used for delay control . |
2. AH3-3 time relay Specifications and parameters
Classification | Multi Range Timer | Multi Range Timer | Multi Range Timer | |||||||
Specification Model | AH3-3 | AH3-B | AH3-NB | |||||||
Dimension | 50H × 40W × 57.5D | 50H × 40W × 57.5D | 50H × 40W × 57.5D | |||||||
Mounting & Socket | Surface(-N) | PF083A (E) | PF083A (E) | PF083A (E) | ||||||
Flush(-Y) | US-08 P3G-08 | US-08 P3G-08 | US-08 P3G-08 | |||||||
Full Timing Range | SEC:1,3,6,10,12,30,60 MIN:3,6,10,12,30,60 HR:3,6,10,12,30 |
A:1S,10S,1M,10M B:3S,30S,3M,30M C:6S,60S,6M,60M D:1M,10M,1H,10H E:3M,30M,3H,30H |
A:1S,10S,1M,10M B:3S,30S,3M,30M C:6S,60S,6M,60M D:1M,10M,1H,10H E:3M,30M,3H,30H |
|||||||
Rated Voltage (V) | AC: 24,110,220,240,380,50/60Hz DC: 12,24 |
AC: 24,110,220,240,380,50/60Hz DC: 12,24 |
AC: 24,110,220,240,380,50/60Hz DC: 12,24 |
|||||||
Indicator Operating | ON-UP operating | ON-UP operating | Time operating flicker | |||||||
O/P Contact | Model | AH3-1 | AH3-2 | AH3-3 | AH3-1 | AH3-2 | AH3-3 | Model A/B | ||
Time Limit 1C | 5A |
|
5A |
|
|
5A |
|
5A | ||
Time Limit 2C |
|
5A |
|
5A |
|
|
5A |
|
||
Instantaneous 1C |
|
|
5A |
|
5A | 5A |
|
5A | ||
Life | Mechanical | 5×106 Times | 5×106 Times | 5×106 Times | ||||||
Electrical | 105 Times | 105 Times | 105 Times | |||||||
Accuracy | Repeat Error | ±1% max | ±1% max | ±1% max | ||||||
Setting Error | ±10% max | ±10% max | ±10% max | |||||||
Voltage Error | ±1% max | ±1% max | ±1% max | |||||||
Temp Error | ±2% max | ±2% max | ±2% max | |||||||
Reset Time | 0.1 sec max | 0.1 sec max | 0.1 sec max | |||||||
Consumed Power | 3VAC | 3VAC | 3VAC | |||||||
Ambient temperature | -10oC~+55oC | -10oC~+55oC | -10oC~+55oC | |||||||
Ambient Huminity | 48~85% RH | 48~85% RH | 48~85% RH | |||||||
Weight | 160g | 160g | 160g |
3. AH3-3 time relay Normal operating conditions and installation conditions:
3.1 The use of the environment: the sea disturbance height of not more than 2000 meters, ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85% -110% rated voltage; in the absence of a serious shock and explosion hazard medium, and medium, non-corrosive metal and undermine the insulation is sufficient gas and dust; in less rain and snow hit areas. 3.2 vertical or horizontal installation. Technical features 1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can be customized); 2, electrical life: ≥ 10 × 104 times; 3, Mechanical life: ≥ 100 × 104 times; 4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1; 5, use the Class: AC-15 DC-13; 6, repeated the error: "1%; 7, reset time: ≤ 1 sec; 8, power consumption: ≤ 1.5W (DH11S ≤ 3W). |
DH48S Digital display time relay is used in the scale of the advanced application specific integrated circuit, LED digital tube display, beautiful appearance, easy installation, digital key switch preset, stable and reliable, high precision, delay range, low power consumption advantages, is widely used in automatic control circuits for delay device.
1. Timing Range:
H:1min-99h99min
M:1s-99min99s
S:0.01s-99.99s
Normal operating conditions and installation conditions
1.1 The use of the environment: the sea disturbance height of not more than 2000 meters, ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85% -110% rated voltage; in the absence of a serious shock and explosion hazard medium, and medium, non-corrosive metal and undermine the insulation is sufficient gas and dust; in less rain and snow hit areas.
1.2 Vertical or horizontal installation.
2.1 Technical Features:
1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can be customized);
2, electrical life: ≥ 10 × 104 times;
3, Mechanical life: ≥ 100 × 104 times;
4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1;
5, use the Class: AC-15 DC-13;
6, repeated the error: "1%;
7, reset time: ≤ 1 sec;
8, power consumption: ≤ 1.5W (DH11S ≤ 3W).
Products Specification:
Part number |
DH48S-A | DH48S-AE | DH48S-2Z | DH48S-1Z | DH48S-E | DH48S-S/2Z | DH48S-S/1Z | |
Indicators | 8 mm LED numeric display | |||||||
Supply voltage | AC24V,110V,220V,380V 50/60Hz DC12V,24V | |||||||
Operating voltage | 85 to 110% of rated supply voltage(90% to 110% at 12 VDC) | |||||||
Power consumption | ≤5W | |||||||
Control output | Time limit | SPDT(2C) | SPDT(2C) | SPDT(2C) | SPDT(1C) | SPDT(1C) | SPDT(2C) | SPDT(1C) |
Instantaneous |
|
SPDT(1C) |
|
|
SPDT(1C) |
|
|
|
Output Max.Load | 5A,250VAC(p.f=1) | |||||||
Output Min.Load | 10 mA,5 VDC | |||||||
Input method | Reset input | no-voltage unput Impedance at short-circuit:max.1kΩ Impedance at open:min.100kΩ residual voltage at short-circuit:max.0.5V |
||||||
Gate input | ||||||||
Repeat accuracy | ±0.3%,±0.05sec(includes variation due to voltage and temperature changes) | |||||||
Setting error | ±0.5%,±0.05sec | |||||||
Resetting system | Power-OFF | |||||||
Resetting time | 0.1 sec max. | |||||||
Connections | 11-pin round socket | 8-pin round socket | ||||||
Mounting | track,surface | |||||||
Operating ambient temperature | -10 to 55 | |||||||
Ambient humidity Operating | 35 to 85%RH | |||||||
Insulation resistance | Insulation resistance 100MΩ min.at500VDC | |||||||
Dielectric strength | 2000V 50/60Hz min between current-carring and non-current-carring parts and between contact and control circuit | |||||||
1500V 50/60Hz min between control output terminals and operating circuit | ||||||||
1000V 50/60Hz min Between contacts | ||||||||
Static immunity | Malfunction:8 KV Destruction:15KV | |||||||
Impulse withstand voltage | 3 kV (between power terminals)1 kV for 24 DC 4.5KV(between current-carrying terminal and exposed non-current-carrying metal parts);1.5 kV for 24VDC |
|||||||
Vibration | Mechanical durability | 10 to 55 Hz with 0.75-mm double amplitude each in 3 directions | ||||||
Malfunction durability | 10 to 55 Hz with 0.5-mm double amplitude each in 3 directions | |||||||
Shock | Mechanical durability | 30G | ||||||
Malfunction durability | 10G | |||||||
Service life | Mechanical | 10 million operations minimum(under no load, at 1,800 operations/hour) | ||||||
Electrical | 100,000 operations minmum at maximum ratings | |||||||
Degree of protection | TECIP30(panel surface) | |||||||
Weight | Approx:150g |
Rated products
General relay MK MY,LY
Thermal relay 3UA LR9 JRS1,JR28
Power relay JQX-38F JQX-40F 1Z JQX-52F JQX-58F JQX-59F JQX-60F JQX-62F 1Z 80A JQX-62F 1Z 120A JQX-62F 2Z 80A
Time relay AH3-N_ ST2P ST3P H3BA(ST4P) H3CR-A8 H3CA-A H3CA-8 ASTP-N/Y AH2-N/Y ATDV-N/Y ASY-2D ASY-3D AH3Y (ST6P)
Electromagnetic relay 58.02 56.02 55.02 55.04 57.02 57.04 60.12 60.13 70.2
Relay socket PYF-08A PYF-08A-E PYF11A PYF14A PF113A-E PF085A PS-08 P2CF-08 PY-08 PY-14 PT-08 PT-14 PTF08A PTF08A-E PTF11A PTF14A PTF14A-E PTF083A PF083A-F PF113A 90.22 90.23 PPF-011 PY-08-0
Solid state relay
other products