Specifications
ACSR/AAC/AAAC/ACAR aluminum strand overhead conductor 
1.18 years factory product 
2.good feature 
3.delivery fast
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage
 levels.
 
Specification:
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6)rear earth aluminum conductor steel reinforced(ACSR/RE)
(7)aluminum conductor aluminum alloy reinforced(ACAR)
AAC Conductor
For use in overhead transmission and distribution systems and as bus connections in substations and 
switchyards. Solid conductors used for mechanical and grounding applications. Classes AA and A are
 used primarily for overhead transmission and primary and secondary distribution,where capacity must 
be maintained, a lighter conductor(compared to ACSR)is desired. Classes B and C are used primarily
 as bus, apparat us connector sand jumpers, where additional flexibility is required.
Specifications
AAC 
1.aluminum stranded conductor 
2.overhead AAC Wire 
3.medium breaking load 
4.bare Al wire
1.Application
1)Classes AA and A are used primarily for overhead transmission and primary and secondary 
distribution, where capacity must be maintained and a lighter conductor (compared to ACSR) is desired, and when conductor strength is not a critical factor.
 Classes B and C are used primarily as bus, apparatus connectors and jumpers, where additional flexibility is required.
2)Classes refer to stranding and are an indication of relative conductor flexibility,
 AA being the least flexible, 
3) the most flexible.
2.Specification
AAC bare conductor meets or exceeds the following international specifications:
? B230 Aluminum 1350-H19 Wire for Electrical Purposes.
? B231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
? GB1179-83 Chinese National Standard
? IEC 60189 Round Wire Concentric Lay Overhead Electrical Stranded Conductor
? BS215-1 Aluminum Conductors and Aluminum Conductors Steel Reinforced
? DIN48201 Aluminum Conductors
3.Construction
Aluminum 1350-H19 wires, concentrically stranded.
4.Standards
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
AAC Technical Date Based on Standard DIN 48201 / DIN EN50182
Code number Area Number of wires Wire diameter Conductor diameter Linear mass Rated strength D.C. resistance at 20oC
mm2 No. mm mm kg/km kN Ω/km
16 15.9 7 1.7 5.1 43.4 3.02 1.7986
25 24.2 7 2.1 6.3 66.3 4.36 1.1787
35 34.4 7 2.5 7.5 93.9 6.01 0.8317
50 49.5 7 3 9 135.2 8.41 0.5776
50 48.3 19 1.8 9 132.9 8.94 0.5944
70 65.8 19 2.1 10.5 180.9 11.85 0.4367
95 93.3 19 2.5 12.5 256.3 16.32 0.3081
120 117 19 2.8 14 321.5 19.89 0.2456
150 147.1 37 2.25 15.8 405.7 26.48 0.196
185 181.6 37 2.5 17.5 500.9 31.78 0.1588
240 242.5 61 2.25 20.3 671.1 43.66 0.1193
300 299.4 61 2.5 22.5 828.5 52.4 0.0966
 
AAAC Conductor
Are made out from aluminum-magnesium-silicon alloy of high electrical conductivity (min 53% IACS) containing magnesium (0.6-0.9%) & silicon (0.5-0.9%) to give it better mechanical properties after treatment. AAAC conductors are made out of 
aluminum alloy 6201. AAAC conductor has a better corrosion resistance and better strength to 
weight ratio and improved electrical conductivity than ACSR conductor on equal diameter basis.
Standards:
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
AAAC Technical Characteristics Based on Standard BS 3242
Code name Nominal aluminum area Stranding and wire diameter Sectional area Approx. overall diameter Approx. mass Calculated D.C. Resistance
at 20oC
Calculated breaking load
mm2 No./mm mm2 mm kg/km Ω/km kN
ALMOND 25 7/2.34 30.1 7.02 82 1.094 8.44
CEDAR 30 7/2.54 35.47 7.62 97 0.9281 9.94
FIR 40 7/2.95 47.84 8.85 131 0.688 13.4
HAZEL 50 7/3.30 59.87 9.9 164 0.5498 16.8
OAK 100 7/4.65 118.9 13.95 325 0.2769 33.3
ASH 150 19/3.48 180.7 17.4 497 0.183 50.65
ELM 175 19/3.76 211 18.8 580 0.1568 59.1
UPAS 300 37/3.53 362.1 24.71 997 0.09155 101.5
 
ACSR Conductor
ACSR is a composite concentric-lay-stranded conductor. Galvanized steel strand or strands form the central core of the conductor, around which is stranded one or more layers of EC Grade Aluminum wires. The steel core may consist of a single strand or a concentric stranded cable of 7, 19, 37, or more wires. Numerous combinations of aluminum and steel strands and layers are possible.
Applications
Conductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Service Performance
1) The permissible long-time operating temperature for aerial conductor is 70oC.
2) Under the circumstance that rare climate is occurring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
3).When connecting conductors,the conductor beside the connecting tube cant be prominent. Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
4) Under installation,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
Product Performance
1) The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.
2) The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.
3) The rated tensile strength of ACSR is denoted with sum of all aluminum conductor tensile strength and steels tensile strength.
a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.
b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.
Material Standard
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
2) The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
3) Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
Standards:
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
ACSR Technical Characteristics Based on Standard BS 215-2
Code name Nominal aluminum area Stranding and wire diameter Sectional area of aluminum Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9