Control cable
1 Product Standard
This product is manufactured according to GB/T9330, IEC60227 and IEC60502 etc.
2 Application
The product is suitable for connection in control, signal, protection circuit and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
3 Operating characteristics
1). Rated power-frequency voltage Uo/U: 450/750V or 0.6/1KV.
2). Max. permissible continuous operating temperature of conductor: 70ºC
3). Max. short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 160ºC
4). The ambient temperature under installation should not below 0ºC. Otherwise, the cable shall be preheated.
5). The recommended bending radius of a cable should be:
Non-armored cable, not less than 6 times of the cable diameter.
Armored cable or copper tape screened cable, not less than 12 times of the cable diameter.
Shielded flexible cabel, not less than 6 times of the cable diameter.
4 Type and Name
5 Production range of cable
1 Product Standard
This product is manufactured according to GB/T9330, IEC60227 and IEC60502 etc.
2 Application
The product is suitable for connection in control, signal, protection circuit and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
3 Operating characteristics
1). Rated power-frequency voltage Uo/U: 450/750V or 0.6/1KV.
2). Max. permissible continuous operating temperature of conductor: 70ºC
3). Max. short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 160ºC
4). The ambient temperature under installation should not below 0ºC. Otherwise, the cable shall be preheated.
5). The recommended bending radius of a cable should be:
Non-armored cable, not less than 6 times of the cable diameter.
Armored cable or copper tape screened cable, not less than 12 times of the cable diameter.
Shielded flexible cabel, not less than 6 times of the cable diameter.
4 Type and Name
Type | Designation |
KVV | Copper conductor,PVC insulated,PVC sheathed control cable |
KVVP | Copper conductor,PVC insulated,PVC sheathed,Braided shield control cable |
KVVP2 | Copper conductor,PVC insulated,PVC sheathed,copper tape shield control cable |
KVV22 | Copper conductor,PVC insulated, PVC sheathed,steel tape armored control cable |
KVV32 | Copper conductor,PVC insulated, PVC sheathed,steel wire armored control cable |
KVVR | Copper conductor,PVC insulated,PVC sheathed flexible control cable |
KVVRP | Copper conductor,PVC insulated,PVC sheathed,Braided shield flexible control cable |
KVVP-22 | Copper conductor,PVC insulated,PVC sheathed,Braided shield, steel tape armored control cable |
KVVP2-22 | Copper conductor,PVC insulated,PVC sheathed,copper tape shield,steel tape armored control cable |
5 Production range of cable
Type | Rated volgage | Cross-sectoion of conductor mm2 |
||||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | |||
Cores | ||||||||||
KVV | 450/750V or 0.6/1kV |
- | 2~61 | 2~14 | 2~10 | |||||
KVVP | - | 2~61 | 2~14 | 2~10 | ||||||
KVVP2 | - | 2~61 | 2~14 | 2~10 | ||||||
KVV22 | - | 7~61 | 2~61 | 2~14 | 2~10 | |||||
KVV32 | - | 19~61 | 7~61 | 2~14 | 2~10 | |||||
KVVR | 2~61 | - | ||||||||
KVVRP | 2~61 | 2~48 | - | |||||||
KVVP-22 | - | 2~61 | 2~14 | 2~10 | ||||||
KVVP2-22 | - | 2~61 | 2~14 | 2~10 |