96 Series Indicator measure Panel Meter/ac amp panel meter

96 TYpe Panel Meter/ac amp panel meter

 

 

CNC, Changcheng- China Famous Brand

www.cncele.com

 

Panel meter is one kind of electric measure indicators with the direct effecting of imitative display. It is suitable for AC and DC output and input distribution circuit, power plant console cabinet, power operating board and different apparatus. It is used to measure DC current, voltage and AC current, voltage, frequency and phase power.

 

Type:

 

OB-96 2MD

96 type Maximum Demand vector table (three needle table)

Accuracy class: 3.0, Instantaneous ammeter 1.5 degree

Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer, accuracy unchanged).

OB-96 H

96 type Cumulative schedule

Maximum display: 99999.99

Voltage: DC12V, 24V; AC110V, 220V, 380V

Frequency: 50/60Hz

 

OB-96 L DC A

96 type 240° Electromagnetic Series (moving coil) DC Ammeter

Accuracy class: 1.5

Specifications: 100uA 150uA 500uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA 300mA 500mA 1A 2A 3A 7.5A 10A 15A

More than 20A connecting 50mV,60mV or 75mV of shunt Outside.

 

OB-96 L DC V

96 type 240° Electromagnetic Series (moving coil) DC Voltmeter

Accuracy class: 1.5

Specifications: 50mV 60mV 75mV 100mV 3V 5V 7.5V 10V 15V 20V 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 500V 600V, More than 600V connecting with Quota Resistors (Rated current 5mA)

 

 

OB-96 L Hz

96 type 240°Frequency Table

Accuracy class: 1.0

Voltage: 110V, 220V, 380V, 415V, 440V

Frequency: 45-55Hz, 45-65Hz, 55-65Hz, 47-53Hz, 57-63Hz, 450-550Hz, 450-650Hz, 550-650Hz.

 

OB-96 Hz

96 type Vibrating reed Frequency Table

Accuracy class: 1.0

Voltage: 110V, 220V, 380V, 415V, 440V

Frequency: 45-55Hz, 45-65Hz, 55-65Hz, 47-53Hz, 57-63Hz

OB-96 COS

96 type Power Factor Meter

Accuracy class: 2.5

3 phase voltage: 110V, 220V, 380V, 415V, 440V/1A or 5A

Single phase voltage: 110V,220V/1A or 5A

Frequency: 50/60Hz

Specification: 0.5cap-1-0.5ind

 

 

OB-96 KW

96 type Power Meter

Accuracy class: 1.5

Single phase voltage: 100V, 110V, 220V

Three-phase three-wire voltage: 100V, 110V, 220V, 380V, 415V(Balanced load or unbalanced load)

Current: Input Current more than 10A connecting inferior 1A or 5A of current

tranformer outside, otherwise allowing direct access according to the current value.

Frequency: 50/60Hz

Specification: 100W, 200W...1KW, 2KW...1MW, 2MW...6MW.

 

OB-96 KW

96 type Power Meter

Accuracy class: 1.5

Three-phase four-wire voltage: 100V, 110V, 220V, 380V, 415 (Balanced load or unbalanced load)

Current: Input Current more than 10A connecting inferior 1A or 5A of current tranformer outside, otherwise allowing direct access according to the current value.

Frequency: 50/60Hz

Specification: 100W, 200W...1KW, 2KW...1MW, 2MW...6MW.

OB-96 MD

96 type Maximum Demand vector table (double needle table)

Accuracy class:3.0

Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer,accuracy unchanged)

OB-96 2MD

96 type Maximum Demand vector table (three needle table)

Accuracy class: 3.0, Instantaneous ammeter 1.5 degree

Specification: 8 minutes 1A, 15 minutes 1A, 30 minutes 1A, 8 minutes 5A, 15 minutes 5A, 30 minutes 5A (As long as the input signal is the same, the dail can arbitrary change according to the change of transformer, accuracy unchanged).