TitleProduct

UL Listed 2hrs Steel Escape Fire Door

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shanghai

  • Validity to:

    Long-term effective

  • Last update:

    2017-11-04 02:46

  • Browse the number:

    61

Send an inquiries
+
Shanghai Yvkui Construction Engineering Consulting Co., Ltd.
Contactaixin:

Mr. Quinn Yi(Mr.)  

Email:

telephone:

phone:

Arrea:

Shanghai

Address:

No. 188 Juting Rd. European Industrial Park Fengxian District, Shanghai, China 201415

Website:

http://shyvkui.aozbao.com/

+

UL (UL Fire Safety Standard):
ANSI/UL 10C Positive Pressure Fire Tests of Door Assemblies
ANSI/UL 10B And CAN/ULC S104, Fire Tests of Door Assemblies
Product:UL Double Leaf Steel Fire Door
Fire Integrity: 2 hours
ULCertificate Number: 20140919-R38072
File No: R38213
Report Reference:R38072-20140919
Frame Size (w*h):2000*2950mm with fixed transom, the height is 725mm.
Frame type: double rabbet, the jamb depth is 150mm comply with UL63 standard.
,150mm,UL63.
Door leaf thickness: 45mm
Apply to brick wall, concrete wall, plaster board wall which comply with UL related standard U415-UL263, U419-UL263,UL263.
UL:2000*2950mm(w*h),,.
:20min, 30min, 45min, 60min, 90min, 120min.
:2000*2950mm,1050*2950mm.1900*2145mm,945*2145mm. ,≤2000*2225mm. ,≤2000*2950mm,,≤1050*2225mm,≤1050*2950mm.
!
Shanghai Yvkui UL Steel fire door is designed as per the project requirement and customer's using habit. The door passed the UL WTDP approved laboratory tests and obtained valid test report and certificate. According to UL rules, we should produce UL marked fire doors in line with the test report. All the hardware used should be UL marked too and with the same hardware preparation. But for the painting color, you still can choose as per your interest from RAL No.
UL fire door is widely used in public buildings at fire zone, fire partition, passage, entrance at stairs, elevator room and so on such as factory, hotel, hospital, stations, compartment, office building, airport, library and so on. All the UL fire doors should be marked with UL label on door frame and leaf separately on hinge position usually.
Our UL approved door frame size : 2000*2950mm( w*h) double leaf without window.
Fire Duration: It can cover 20min, 30min, 45min, 60min, 90min, 120min UL steel fire doors.
Type: It can cover double leaf door, the frame size ≤2000*2950mm, single door frame size ≤1050*2950mm with fixed transom panel which is 725mm in height; It can cover single or double leaf doors without transom or smaller sized.
It can cover the double door leaf size≤1900*2145mm, single door leaf size ≤945*2145mm.
.
ULHardware assembly simple description:
Hinges: flap type, hinges comply with NFPA80
Lock: hand lock type comply with UL 10C, BHMA A 156.13/36
Closer: comply with UL10C, UL 228,BHMA A156.4
Panic lock: comply with UL 10C, UL305, BHMA A 156.3
Specifications for steel door and frame preparation for hardware comply with ANSI/DHI A115
other products