TitleProduct

Test and Measuring Instruments Gf302 Portable Multifunction Instrument Calibrator

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-08-04 14:57

  • Browse the number:

    220

Send an inquiries
+
Beijing GFUVE Electronics Co., Ltd.
Contactaixin:

Mr. Andy Huang(Mr.)  

Email:

telephone:

phone:

Arrea:

Beijing

Address:

Bldg,1-1006,Joy Mansion,No.99 Chaoyang North Road, Chaoyang District, Beijing, China 100025

Website:

http://guangfuhui.aozbao.com/

+

Test and Measuring Instruments GF302 Portable Multifunction Instrument Calibrator
Application of Test and measuring instruments GF302 portable multifunction instrument Calibrator
It is suitable for power plant and power grid companies measuring and testing department and instrumentation classes, and national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc.
Introduction
GF302 Portable Multifunction Instrument Calibrator is suitable for power plant and power grid companies for the following function: measuring and testing department and instrumentation classes, national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc. The core technology function with digital signal processor (DSP) and 16 high-speed digital converters composed of high precision work frequency communication terminal. The signal source is DSP and 16 high-speed digital-to-analog converters, it can control the sine wave and distortion wave signal source.
FUNCTIONS AND FEATURES
  • All kinds of electric measurement transducer can be checked, including AC/DC voltage transducer, AC/DC current transducer, frequency transducer, phase transducer, single/ three-phase AC active power transducer, and 3-phase reactive power transducers.
  • Check all kinds of electric measurement indicating meter, including AC/DC voltmeter, AC/DC ammeter, frequency meter, phase meter, single three-phase acjige active power meter, three-phase ac reactive power meter, synchronous meter, etc.
  • Test single-phase, three-phase electronic, mechanical watt-hour meter or energy meter/ kWh meter error.
  • Calibrate AC sample device, RTU, measurement device error.
  • 5The built-in electric measurement transducer, electric measurement instrument and meter instructions of verification procedures, can fully automatic or semi-automatic for verification, and save 1000 group check data.
  • It can be used as voltage source, current source and power source with high precision, and it is a high stability standard resource.
  • 8-inch big screen color display and English interface.
  • For the software calibration, you don't need to open the case, it's stable and reliable.
  • Voltage output terminal with short circuit, current output terminal open protection and power amplifier overheating protection function.
  • With automatic failure detection function, shows fault part, the convenience users check line.
  • With USB port, it can connect computer for data management or controlled by PC.
 
PARAMETERS
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supply Single phase AC 220V±10% or 110V±10%, 50/60Hz
Communication port USB, RS232, RS485, LAN
AC Voltage output
Range(U1,U2,U3) 50V, 100V, 200V, 400V, 600V
Adjustment range (0 - 120)% RG
Adjustment resolution 0.01% RG, 0.1% RG, 1% RG, 10% RG
Stability 0.01% /1min
Distortion ≤0.2% (non-capacitive load)
Max. output load 25VA for each phase
Accuracy 0.05% RG
AC Current output
Range(I1,I2,I3) 0.5A, 1A, 2.5A, 5A, 10A, 20A
Adjustment range (0 - 120)% RG
Adjustment resolution 0.01% RG, 0.1% RG, 1% RG, 10% RG
Stability 0.01% /1min
Distortion ≤0.2% (non-capacitive load)
Max. output load 25VA for each phase
Accuracy 0.05% RG
AC Power output
Active output stability 0.01%RG/1min
Reactive output stability 0.02%RG/1min
Active accuracy 0.05% RG
Reactive accuracy 0.1% RG
Frequency output
Adjustment range 45-65Hz
Adjustment resolution 1Hz, 0.1Hz, 0.01Hz and 0.001Hz
Resolution 0.001Hz
Accuracy 0.002Hz
Power factor output
Adjustment range -1 to 0 to +1
Adjustment resolution 0.0001
Resolution 0.0005
Phase output
Adjustment range 0°-359.999°
Adjustment resolution 10°, 1°, 0.1°, 0.01°
Resolution 0.001°
Accuracy 0.05°
Harmonic configuration
Times 2 to 31
Content 0-40%
Phase 0°-359.999°
Configuration error (10% RD + 0.1%), RD refers to the configuration value of harmonic contents
DC Voltage output
Range 75mV, 75 V, 150 V, 300 V, 500V, 1000 V
Adjustment range (0-120)% RG
Adjustment resolution 0.01% RG, 0.1% RG, 1% RG, 10% RG
Stability 0.01% RG / 1 min
Distorting ≤0.2% (non-capacitive load)
Output load 25VA
Accuracy 0.05% RG
Ripple contents ≤1%
DC Current output
Range 0.5 A,1A, 2.5 A, 5 A, 10A, 20 A
Adjustment range (0-120)% RG
Adjustment resolution 0.01% RG, 0.1% RG, 1% RG, 10% RG
Stability 0.01% RG / 1min
Distortion ≤ 0.2% (non-capacitive load)
Output load 25VA
Accuracy 0.05% RG
Ripple contents ≤1%
Energy Error
Active error 0.05% RG
Reactive error 0.1% RG
DC Input Voltage Measurement
Range 0 to ±20V
Measurement range (0-120)% RG
Accuracy 0.01% RG
Resolution 0.001% RG
DC Input Current Measurement
Range 0-20mA
Measurement range (0-120)% RG
Accuracy 0.01% RG
Resolution 0.001% RG
Mechanical parameters
Dimensions (W×H×D) (mm) 460x430x185
Weight (kg) 20
Environmental conditions
Working temperature 0°C to 40°C
Relative humidity ≤85%