Two Wire 4-20mA Voltage Signal Isolation Transmitter (ISO V-4-20mA)
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Guangdong
-
Validity to:
Long-term effective
-
Last update:
2017-08-15 16:43
-
Browse the number:
273
+
Shenzhen Sunyuan Technology Co., Ltd.
- Contactaixin:
Mr. Sandy Xia(Mr.)
- Email: telephone: phone:
-
Arrea:
Guangdong
Address:2/F, 1 Bldg., Shenhua Technology Park, Meixiu Rd., Futian District, Shenzhen, Guangdong, China 518049
- Website:
+
Two-wire Loop Powered 0-5V/0-10V to 4-20mA Transmitter/Converter IC
ISO V-4-20mA
Features:
Two-wire sensor voltage signal isolation and conversion
Accuracy error grade: Non-isolation type: 0.1; Isolation type: 0.2.
Inner linearization process and long line compensation circuit. (Non-linearity<0.05%)
Isolation between signal input and output is 3KVDC (total isolation type)
The power supply range for sensor: 12-32VDC
Low input equivalent resistance, high linearity.
Low cost, small size, IC package, DIN35.
Industrial field operation temperature: - 40 ~ + 85 º C
Applications:
PLC/DCS directly gathers voltage signals from sensor.
Displacement signal, potentiometer signal data acquisition isolation and control.
Interference rejection of industrial field ground
Converts weighing signal into standard 4-20mA analog signal.
Pressure signal acquisition and distribution
Analog signal long-term distortionless transmission
Bridge (weighing) detecting circuit voltage signal distribution and transmission
ISO V-4-20mA
Features:
Two-wire sensor voltage signal isolation and conversion
Accuracy error grade: Non-isolation type: 0.1; Isolation type: 0.2.
Inner linearization process and long line compensation circuit. (Non-linearity<0.05%)
Isolation between signal input and output is 3KVDC (total isolation type)
The power supply range for sensor: 12-32VDC
Low input equivalent resistance, high linearity.
Low cost, small size, IC package, DIN35.
Industrial field operation temperature: - 40 ~ + 85 º C
Applications:
PLC/DCS directly gathers voltage signals from sensor.
Displacement signal, potentiometer signal data acquisition isolation and control.
Interference rejection of industrial field ground
Converts weighing signal into standard 4-20mA analog signal.
Pressure signal acquisition and distribution
Analog signal long-term distortionless transmission
Bridge (weighing) detecting circuit voltage signal distribution and transmission
Input | Output | Power supply |
0-2.5V | 4-20mA Loop powered |
None loop powered |
0-3.3V | ||
0-5V | ||
0-10V | ||
1-5V |